Islatrol Plus Active Tracking
Provides continuous sine wave active tracking filtration plus high energy
protection from spikes, transients, and noise on the AC power line. Both normal
(line to line or line to neutral) and common (line and/or neutral to ground)
modes are protected. These units are bi-directional, offer excellent EMI/RFI
noise rejection and exceed the lowest UL1449 suppressor clamping categories,
50/60 Hz, single phase. We recommend the use of one of the three models listed
below with your antique radio for continued protection from hazardous
voltage variants.
Protect your radio investment with a surge protector and have
the peace of mind that your
antique radio is safe.
LRIC+102 - Your Price
$118.50
order
now!
2.5 AMP Rating output. Use
for light duty applications
LRIC+105 - Your Price
$160.50
order
now!
5.0 AMP Rating output. Use
for medium duty applications
LRIC+107 - Your Price $206.00
order
now!
7.5 AMP Rating output. Use for
medium/heavy duty applications
LRIC+115 - Your Price $312.50 order
now!
15.0 AMP Rating output. Use for heavy
duty applications
Islatrol
power line filters offer the original Active Tracking technology to guard
against commonly occurring, but very damaging, lower energy transients and
offers excellent noise reduction. Islatrol Plus and Islatron combines rugged,
high energy current diverters with the Active Tracking Filter to provide
protection against the full spectrum of voltage transients and surges.
|
Line Cord Unit Shown 
|

|
Series-connected high-frequency noise filter with transient
protection. Offers the flexibility of either receptacle/line cord
connection or hard-wired connection to critical loads (up to 30
amperes). Applications include industrial or office equipment,
computers placed in harsh environments.
|
|
|

|
|

|
Typically
reduces normal mode transients to
+/– 2 volts
|
|

|
Surge
current capacity—45,000 Amps
|
|

|
Transient
protection in all modes: line to neutral, line to ground, and
neutral to ground
|
|

|
LED
power indication
|
|

|
UL
1283, CSA recognized
|
|

|
10-year warranty
|
|
|
|
|
|
|

|
|
MCOV
|
|
120
Volt
|
150
VRMS
|
|
240
Volt
|
275
VRMS
|
|
Line
Frequency
|
47–63
Hz
|
|
Response
Time
|
|
Normal
Mode
|
<
0.5 ns
|
|
Common
Mode
|
<
5 ns
|
|
Operating
Temperature
|
|
–40ºC
to +45ºC at Full Load
|
|
Derate
Linearly to 60% at +70ºC
|
|
Operating
Humidity
|
0%
to 95%
|
|
Peak
Surge Current Capability (8 x 20 µs)
|
|
Line
to Neutral
|
15,000
Amps
|
|
Line
to Ground
|
15,000
Amps
|
|
Neutral to Ground
|
15,000
Amps
|
|
Load
Surge Current Rating
|
|
10
mSec
|
5
x Nominal
|
|
1
sec
|
3
x Nominal
|
|
10 Sec
|
2
x Nominal
|
|
Packaging
|
|
•
High-Impact Plastic Case
• Vacuum Impregnated Magnetics
• Epoxy Encapsulated
|
|
Frequency
Response
(Forward-Reverse)
|
|
Normal
Mode
|
100
kHz to 50 MHz—
90 dB Min
|
|
Common
Mode
|
5
MHz to 50 MHz—
60 dB Min
|
|
Typical Category A Ringwave
(6 kV, 200A, 100 kHz)
|
MODEL
|
NORMAL
|
COMMON
|
|
IC+102
/ LRIC+102
|
1.0
/ 0.9
|
302
/ 287
|
|
IC+105
/ LRIC+105
|
0.7
/ 0.8
|
292
/ 307
|
|
IC+107
/ LRIC+107
|
0.7
/ 0.7
|
302
/ 293
|
|
IC+115
/ LRIC+115
|
0.7
/ 0.7
|
304
/ 306
|
|
IC+130
/ IC+202
|
0.5
/ 1.1
|
306
/ 536
|
|
IC+205
/ IC+207
|
1.5
/ 0.8
|
628
/ 616
|
|
IC+215
/ IC+230
|
0.6
/ 0.9
|
572
/ 566
|
Typical
Category B Ringwave
(6 kV, 500A, 100 kHz)
|
MODEL
|
NORMAL
|
COMMON
|
|
IC+102
/ LRIC+102
|
178
/ 188
|
302
/ 285
|
|
IC+105
/ LRIC+105
|
162
/ 191
|
291
/ 300
|
|
IC+107
/ LRIC+107
|
173
/ 190
|
300
/ 298
|
|
IC+115
/ LRIC+115
|
153
/ 149
|
307
/ 309
|
|
IC+130
/ IC+202
|
241
/ 302
|
299
/ 532
|
|
IC+205
/ IC+207
|
378
/ 336
|
594
/ 596
|
|
IC+215
/ IC+230
|
272
/ 342
|
548
/ 578
|
Note: All
measurements in volts. IEEE test results with no AC applied. Normal
mode—L1-N or L1-L2; Common mode—L-G, N-G or L1-G, L2-G.
|
|

|
|
120
VAC Models with Barrier Strip at Input & Output / with Wire
Leads at Input & Output (WL)
|
MODEL
|
RATED
OUTPUT
(AMPS)
|
CASE
DIM. (in.)
A x B x C
|
MOUNTING
FLANGE DIM. (in.)
D x E x F x G
|
SCREW
SIZE
|
WGHT.
(lbs.)
|
|
IC+102/IC+102WL
|
2.5
|
4x2.88x1.81
|
4.38x2.12x5.31x0.19
|
#6
|
1.0
|
|
IC+105/IC+105WL
|
5.0
|
4x2.88x1.81
|
4.38x2.12x5.31x0.19
|
#6
|
1.3
|
|
IC+107/IC+107WL
|
7.5
|
4.75x4.75x2.35
|
5.25x3.50x6.25x0.19
|
#6
|
2.0
|
|
IC+115/IC+115WL
|
15
|
6.25x4.75x2.35
|
6.75x3.50x7.75x0.19
|
#8
|
3.5
|
|
IC+130/IC+130WL
|
30
|
7.75x4.75x2.35
|
8.25x3.50x9.00x0.19
|
#8
|
6.0
|
|
|
120
VAC Models with 5-Foot Line Cord & Single NEMA 5-15 Receptacle
|
MODEL
|
RATED
OUTPUT
(AMPS)
|
CASE
DIM. (in.)
A x B x C
|
MOUNTING
FLANGE DIM. (in.)
D x E x F x G
|
SCREW
SIZE
|
WGHT.
(lbs.)
|
|
LRIC+102
|
2.5
|
4.5x3.0x1.88
|
N/A
|
N/A
|
1.3
|
|
LRIC+105
|
5.0
|
4.5x4.5x2.38
|
N/A
|
N/A
|
2.0
|
|
LRIC+107
|
7.5
|
6.0x4.5x2.38
|
N/A
|
N/A
|
2.3
|
|
LRIC+115
|
15
|
7.5x4.5x2.38
|
N/A
|
N/A
|
4.0
|
|
|
240
VAC Models with Barrier Strip at Input & Output / with Wire
Leads at Input & Output (WL)
|
MODEL
|
RATED
OUTPUT
(AMPS)
|
CASE
DIM. (in.)
A x B x C
|
MOUNTING
FLANGE DIM. (in.)
D x E x F x G
|
SCREW
SIZE
|
WGHT.
(lbs.)
|
|
IC+202/IC+202WL
|
2.5
|
4x2.88x1.81
|
4.38x2.12x5.31x0.19
|
#6
|
1.3
|
|
IC+205/IC+205WL
|
5.0
|
4.75x4.75x2.35
|
5.25x3.50x6.25x0.19
|
#6
|
2.0
|
|
IC+207/IC+207WL
|
7.5
|
6.25x4.75x2.35
|
6.75x3.50x7.75x0.19
|
#8
|
3.3
|
|
IC+215/IC+215WL
|
15
|
7.75x4.75x2.35
|
8.25x3.50x9.00x0.19
|
#8
|
5.8
|
|
IC+230/IC+230WL
|
30
|
7.75x4.75x2.35
|
8.25x3.50x9.00x0.19
|
#8
|
6.0
|
|
|
|

|
|

|
|

|
|

|